Oakton Benchtop CON 700, CON 2700 and PC 700 and PC 2700 Conductivity Meters

 
Specifications CON 700 CON 2700 PC700 PC2700


Oakton Benchtop CON 700, CON 2700 and PC 700 and PC 2700 Conductivity Meters Oakton Benchtop CON 700, CON 2700 and PC 700 and PC 2700 Conductivity Meters Oakton Benchtop CON 700, CON 2700 and PC 700 and PC 2700 Conductivity Meters Oakton Benchtop CON 700, CON 2700 and PC 700 and PC 2700 Conductivity Meters
Catalog No. AY-35411-00 AY-35412-00 WW-35413-00 WW-35414-00
Range (pH) - - 2.00 to 16.00 2.000 to 20.000
Range (mV) - - ± 2000 ± 2000
Range (Conductivity) 0 µS to 200 mS 0 µS to 500 mS 0 to 200 mS 0 to 500 mS
Range (TDS) 0 to 200 ppt 0 to 500 ppt 0 to 200 ppt 0 to 500 ppt
Range (Salinity) - 0 to 80 ppt - 0 to 80 ppt
Range (Resistivity) - 0 to 20.00 M ohm - 0 to 20.00 M ohm
Range (ISE) - - - 0 to 19999 ppm
Range (Temperature °C) 10 to 110 10 to 110 10 to 110 10 to 110
Range (Temperature °F) 14 to 230 14 to 230 14 to 230 14 to 230
Resolution (pH) - - 0.1/0.01 0.1/0.01/0.001
Resolution (Temperature) 0.1 0.1 0.1 0.1
Resolution (mV) - - 0.1/1 0.1/1
Resolution (Conductivity) 0.01, 0.1 µS; 0.001, 0.01, 0.1 mS 0.01, 0.1 µS; 0.001, 0.01, 0.1
mS
0.01, 0.1 µS; 0.001, 0.01, 0.1 mS 0.01, 0.1 µS; 0.001, 0.01, 0.1 mS
Resolution (TDS) 0.01, 0.1 ppm, 0.001, 0.01, 0.1 ppt 0.01, 0.1 ppm, 0.001, 0.01, 0.1 ppt 0.01, 0.1 ppm, 0.001, 0.01, 0.1 ppt 0.01, 0.1 ppm, 0.001, 0.01, 0.1 ppt
Resolution (Resistivity) - 0.01 m ohm, 0.001, 0.01 k ohm, 0.01, 0.1 ohm - 0.01 m ohm, 0.001, 0.01 k ohm, 0.01, 0.1 ohm
Resolution (ISE) - - - Up to 3 digits
Resolution (Salinity) - 0.01, 0.1 ppm; 0.001, 0.01 ppt - 0.01, 0.1 ppm; 0.001, 0.01 ppt
Accuracy (pH) - - ±0.01 pH ±0.002 pH
Accuracy (Temperature) ±0.5°C ±0.5°C ±0.5°C ±0.5°C
Accuracy (mV) - - ±0.2 mV or 0.05%, whichever is greater ±0.2 mV or 0.05%, whichever is greater
Accuracy (Resistivity) ±1% full-scale ±1% full-scale ±1% full-scale ±1% full-scale
Accuracy (ISE) - - - ±0.5% of reading
Accuracy (Conductivity) ±1% full-scale ±1% full-scale ±1% full-scale ±1% full-scale
Accuracy (TDS) ±1% of reading ±1% of reading ±1% of reading ±1% of reading
Accuracy (Salinity) ±1.0% full-scale ±1.0% full-scale ±1.0% full-scale ±1.0% full-scale
Temperature compensation Automatic or manual Automatic or manual Automatic or manual Automatic or manual
Display LCD LCD LCD LCD
Interface RS-232 RS-232 - RS-232
Calibration Up to 6 points Up to 6 points Up to 6 points Up to 6 points
Connections - - BNC, Temp 2.5mm BNC, Temp 2.5mm
Power 100 to 240 VAC, 50/60 Hz 100 to 240 VAC, 50/60 Hz 100 to 240 VAC, 50/60 Hz 100 to 240 VAC, 50/60 Hz
Datalogging (points) 100 500 100 500
Dimensions (" W) 6-7/8 6-7/8 6-7/8 6-7/8
Dimensions (" H) 2-3/4 2-3/4 2-3/4 2-3/4
Dimensions (" L) 6-1/8 6-1/8 6-1/8 6-1/8
 
 
 
 
 
 
 